Open Circuit Cooling Water Pump, Double Suction Pump

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Years
Manufacturer/Factory, Trading Company
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Fast Delivery
The supplier can deliver the goods within 30 days
Low MOQ
The MOQ for the supplier's products is 1
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (8)
  • Open Circuit Cooling Water Pump, Double Suction Pump
  • Open Circuit Cooling Water Pump, Double Suction Pump
  • Open Circuit Cooling Water Pump, Double Suction Pump
  • Open Circuit Cooling Water Pump, Double Suction Pump
  • Open Circuit Cooling Water Pump, Double Suction Pump
  • Open Circuit Cooling Water Pump, Double Suction Pump
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Corrosion resistant alloy
  • Product Feature
  • Performance parameters
  • Company presentation
  • You may also like
Overview

Basic Info.

Model NO.
ES
Max.Head
>150m
Max.Capacity
>400 L/min
Driving Type
Motor
Material
Stainless Steel
Structure
Single-stage Pump
Assembly
Liquid Pumps
Power
Electric
Start Up
Electric Pump
Type
Positive-Displacement Pump
Application
Submersible Pump, Clarified Water Pump, Sewage Pump, Slurry Pump, Oil Transfer Pump, Chemical Pump
Industry
Air Conditioning Pump
Media
Sea Water Pump
Performance
Explosion-Proof Pumps
Theory
Centrifugal Pump
Power Rate
Max. 3500kw
Paint
Blue or Customized
Impeller
Grey Iron/ Cast Steel/ Stainless Steel
Medium Temperatures
Below 80 Degree
Shaft Seal
Static Seal/ Mechanical Seal
Import and Export Flange
GB, JIS. ANSI. API. Jpi etc.
Transport Package
Wood Case
Trademark
BLOSSOM
Origin
China
Production Capacity
300set/Year

Product Description


Product Description
Open Circuit Cooling Water Pump, Double Suction Pump
Open Circuit Cooling Water Pump, Double Suction PumpOpen Circuit Cooling Water Pump, Double Suction Pump
Open Circuit Cooling Water Pump, Double Suction PumpOpen Circuit Cooling Water Pump, Double Suction PumpOpen Circuit Cooling Water Pump, Double Suction Pump
Eco-friendly
The traditional grease-lubricated bearings (including both rolling contact bearings and sliding contact bearings) are replaced with self-lubricating sliding contact bearings, eliminating the pollution hazard to both the transmission medium and the site environment.
 
Energy-saving

Lubricant is no longer needed
Less material used:
  1. Traditional bearing body removed
  2. Shorter pump shaft - reduce one mechanical seal

Increased efficiency:
  1. Hydraulic model improved and optimised
  2. Changes in structure and lubrication methods improve efficiency

Maintenance-free and low operation cost
  1. Maintenance-free bearing eliminates manual inspection
  2. The non-driving end seal adopts static seal technique,eliminating one mechanical seal

Longer bearing life

The service life of traditional ball bearings is affected by the operating conditions. The general design life is about 2-5 years. With this product, the bearing service life can reach 5-10 years.

Safer, smoother, and more reliable operation
Carefully designed to reduce vibration and noise.
The non-driving end adopts static sealing, which reduces one point of failure.
The bearing cage of the traditional double-suction pump is removed, the length of the pump shaft is shortened, improving the operational stability of the pump.
Diaphragm coupling for the full range of pumps.

Wider application
A variety of material combinations can be chosen according to different purposes, allowing for a wider range of application.

Simpler structure, easier repair
The original advantages remaining unchanged - the casing is split into two parts. Inspection work only needs tlhe upper casing to be dismounted, instead of the main distribution piping.Open Circuit Cooling Water Pump, Double Suction PumpOpen Circuit Cooling Water Pump, Double Suction PumpOpen Circuit Cooling Water Pump, Double Suction Pump



Open Circuit Cooling Water Pump, Double Suction Pump

Inlet diameter(mm) Φ150 ~ φ500 φ600 ~ φ1200
Frequency(Hz) 50 60 50 60
Flow (m3/min) 5~40 6~50 40~200 45~250
Head(m) 5~130 8~180 10~120 15~180
Pump stage  High speed  2,4 2,4 6,8,10,12 6,8,10,12
Low speed  4,6 4,6 8,10,12,14 8,10,12,14
 
  Standard specification  Special specification 
Extraction medium  Clear water, industrial water, river water  Sea water, paper pulp liquid (water-like), organic liquid fertilizer, medium with impurities 
Medium temperatures Below 80ºC 80ºC~300ºC
Shaft seal Static seal/
Mechanical seal
Static seal/
Mechanical seal
Bearing and lubricant Maintenance-free
water-based lubricant
Special maintenance-free self-lubricating
Rotating direction Clockwise
(From the prime mover) CW
Anti-clockwise
CCW
Import and export flange GB JIS. ANSI. API. JPI etc.
Inlet & outlet direction Horizontal inlet,
horizontal outlet
As per customer requirements
Drive method Electric motors, internal combustion engines, steam turbines, etc. Electric motors, internal combustion engines, steam turbines, etc.
Detailed Photos

 

Open Circuit Cooling Water Pump, Double Suction Pump
Corrosion resistant alloy

 

Component Standard specification Special specification
Pump casing & Casing cover Grey iron/ Ductile iron Stainless steel/
Corrosion-resistant stainless steel
Impeller Grey iron/
Cast steel/
Stainless steel
Corrosion-resistant stainless steel/
Bronze
Shaft Carbon steel Stainless steel/
Corrosion-resistant stainless steel
Bearing Maintenance-free water-based lubricant  Special maintenance-free self-lubricating 
Seal ring  Carbon steel/
Copper 
Grey iron/
Stainless steel/
Corrosion-resistant stainless steel
 
Product Feature

Pump casing & Casing cover

The pressure chamber of ES type double suction pump has a trapezoidal cross-section. To avoid shape distortion due to casting errors, the flange of the casing cover is designed to be slightly larger than the flange of the casing.
For a split casing pump with a lower head, a single-shell structure is used. To reduce the pressure pulsation during the operation, the diaphragm tongue of the pump pressure chamber is designed with an inclined shape.
For a split casing pump with a higher head, the radial force generated when the pump is running is large. Hence a double volute chamber structure is adopted.
Open Circuit Cooling Water Pump, Double Suction PumpOpen Circuit Cooling Water Pump, Double Suction Pump
Open Circuit Cooling Water Pump, Double Suction Pump

Impeller
The impeller of ES type double-suction pump adopts a structure in which two identical single-suction blades are placed back-to-back. The structure is symmetrical, the liquid flows into the impeller symmetrically from the suction chamber, and the generated axial forces cancel each other out. The runner of the impeller is polished and smoothed by tools like grinding wheels. The thickness of the impeller blades is uniform, and they are polished very thinly at the inlet. The inlet of the blades take the shape of a circular arc, which improves the anti-cavitation performance of the pump.
Seal ring and Impeller seal ring
The sealing ring of ES double suction pump is designed to protect the pump casing and cover. In order to prevent the sealing ring from rotating when the pump is running, it needs to be fixed with a dowel pin. To facilitate installation, the positioning groove of the pin is provided on the middle opening surface of the casing cover or the pump casing.
Similarly, the impeller sealing ring is a part designed to protect the impeller. When the pumped medium contains solid particles, or, the material of the impeller and the seal ring are the same (when specified by the user), in order to reduce the operating cost of the pump, consider using the impeller seal ring. The impeller sealing ring is generally installed with hot fitting.
Shaft
The shaft of ES double-suction pump has two directions of rotation: clockwise (CW) and counter-clockwise (CCW). In this way, the location of the prime mover can be selected according to the physical space of the pump installation site.
Bearing
The bearing of the ES type double suction pump is a self-lubricating bearing located inside the pump body to support the rotor components. Its biggest advantage is maintenance-free (that is, no daily maintenance is required). It has the advantages of small installation space, stable operation, high efficiency, low operation and maintenance cost.
Shaft seal
The non-driving end of the ES double-suction pump is sealed by static seal; whilst the driving end uses a high-performance cartridge mechanical seal, making it more reliable and stable; it has more convenient maintenance and lower cost.
Water pipe
The piping of ES type double suction pump includes headrace pipe, cooling water control valve, cooling water flow indicator and cooling pipe.
The headrace pipe is to discharge the air in the pump chamber. The pipeline is designed to - either inject water into the pump chamber or use a vacuum pump to suck out the air in the pump chamber
Cooling water control valve and cooling water flow indicator are used to control and display the cooling water flow respectively.
Cooling pipe is designed for cooling the bearings.
Connecting parts
The coupling parts of ES double suction pump generally use diaphragm coupling, elastic pin coupling or gear coupling.
 Open Circuit Cooling Water Pump, Double Suction Pump
Performance parameters
Model ES SERIES
Flow(m³/h) 246-11100
Head(m) 7.4-12
Eff. (%) 76-90
Speed(rpm) 1490/1460/990/740/493
Shaft power(kw) 6-2989.7
Motor power(kw) 7.5-3550
NPSHR(m) 2-6.6
 Open Circuit Cooling Water Pump, Double Suction PumpOpen Circuit Cooling Water Pump, Double Suction PumpOpen Circuit Cooling Water Pump, Double Suction Pump
Company presentation
Open Circuit Cooling Water Pump, Double Suction Pump

Open Circuit Cooling Water Pump, Double Suction PumpOpen Circuit Cooling Water Pump, Double Suction Pump

Open Circuit Cooling Water Pump, Double Suction PumpRFQ

Q1. What is your terms of packing? 
A: Generally, we pack our goods in neutral export wooden case . If you have legally registered patent, we can pack the goods in
wooden case with your own marks after getting your authorization letters.

Q2. What is your termsof payment? 
A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance. 

Q3. What is your terms of delivery? 
A: EXW, FOB, CFR, CIF, etc.

Q4. How about your delivery time?
A: Generally, it will take from 10 dasys to 30 days after receiving your advance payment according to the pump's material. The
specific delivery time also depends on the items and the quantity of your order.

Q5. Can you produce according to the samples?
A: Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures. 

Q6. What is your sample policy? 
A: We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and the courier cost.

Q7. Do you test all your goods before delivery?
A: Yes, we have 100% test the pumps before delivery .

Q8: How do you make our business long-term and good relationship? 
A. We keep good quality and competitive price to ensure our customers benefit ; 
B. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they are from.
You may also like
Open Circuit Cooling Water Pump, Double Suction Pump
Open Circuit Cooling Water Pump, Double Suction Pump
Open Circuit Cooling Water Pump, Double Suction Pump

 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier